Multiparameter DO Meter – HI2040

The smart, slim-line design means edge can be used as a hand held, wall mount or bench top meter. Combined with sophisticated technology, it delivers fast accurate results with laboratory grade precision whichever format you choose to use. Cutting-edge design, capacitive touch keypad and an intuitive user interface are just some of the attributes that make this meter stand out. DO is measured through a unique digital electrode. Connected via an easy plug-in 3.5mm connector, this smart electrode enables edge to automatically recognise and store sensor type, ID and calibration information. Programmed for basic and advanced modes, edge offers simplified screen features for routine measurements or detailed data display.

This product is currently out of stock and unavailable.

Digital Electrodes

edge® electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge® once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.

Clark Type Polarographic DO Probe

edge®HI764080 DO probe has an integrated temperature sensor incorporated into the thin ½” PEI body for automatic temperature compensation of dissolved oxygen measurements. The HI764080 probe uses screw on replaceable caps with a PTFE (Polytetrafluoroethylene) membrane that is easily replaced in the field as well in the lab. The supplied HI7041S is a concentrated Potassium Chloride fill solution used with the Clark-type polarographic technology. With this technology, an external voltage is applied to the platinum cathode and silver anode to establish a current that is proportional to the concentration of oxygen in a solution.

3.5 mm Probe Input

Plugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.

SKU HI2040-01
Name ® Multiparameter DO Meter – HI2040
pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV
pH Resolution 0.001 pH, 0.01 pH, 0.1 mV
pH Accuracy ±0.002 pH, ±0.01 pH, ±0.2 mV
pH Calibration Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*
pH CAL Check (electrode diagnostics) glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time
EC Resolution 0.01 µS/cm, 00.1 µS/cm, 0.01 µS/cm, 0.01 mS/cm, 00.1 mS/cm
EC Accuracy ±1% of reading (±0.05 µS/cm or 1 digit, whichever is greater)
EC Calibration 1 Cell Factor calibration; 6 standards available: 84, 1413 µS/cm, 5.00, 12.88, 80.0, 111.8 mS/cm, 1 point offset: 0.00 µS/cm
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)