Laboratory Research Grade Benchtop pH/mV and EC/TDS/Salinity/Resistivity Meter – HI5521

The HI5521 is rich in features including data logging, alarm limits, comprehensive GLP, and many more while retaining simplicity in use with both dedicated key for routine operation and virtual keys that guide the user through setup options. The HI5521 ensures confidence in pH measurements with the exclusive Hanna Instruments CAL Check feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.

  • Capacitive touch keypad
  • Two independent channels
  • CAL Check Probe Diagnostics

This product is currently out of stock and unavailable.

Features at-a-glance

Highly Customizable User Interface – The user interface of the HI5521 allows the user to show measurements in various modes: basic measurement with or without GLP information, real-time graphing, and logging data. Calibration stability criteria can be adjusted from fast, moderate, and accurate. Programmable alarm limits can be set to inside or outside allowable limits.

Color Graphic LCD – The HI5521 features a color graphic LCD with on-screen help, graphic, and custom color configurations. The display allows for real-time graphing and the use of virtual keys provide for an intuitive user interface.

Capacitive Touch – The HI5521 features sensitive capacitive touch buttons for accurate keystrokes when navigating menus and screens. There are four dedicated keys that are used for routine operations including calibration and switching measurement modes and four virtual keys that change based upon use. The capacitive touch technology ensures the buttons never get clogged with sample residue.

Four Ring Conductivity Probe – All readings are performed with the HI76312 four-ring conductivity probe that has a built in temperature sensor for automatic temperature correction.  The four rings are made with platinum and the body of the electrode is made of Polyetherimide (PEI) plastic that is resistant to many harsh chemicals.  The four-ring design allows for this probe to be used over a wide range of measurements.

Choice of Calibration – Automatic buffer recognition, semiautomatic, and direct manual entry pH calibration options are available for calibrating up to five points, from a selection of eight standard buffers and up to five custom buffers.  For the conductivity channel the calibration can be set to automatic standard recognition or user entry along with a choice of single or multi-point. Calibration can be performed up to four points when multi-point is selected.

SKU HI5521-02
Product Name Laboratory Research Grade Benchtop pH/mV and EC/TDS/Salinity/Resistivity Meter – HI5521
Quote Required Yes
pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH
pH Resolution 0.1 pH / 0.01 pH / 0.001 pH
pH Accuracy ±0.1 pH / ±0.01 pH / ±0.002 pH ± 1LSD
pH Temperature Compensation automatic or manual from -20.0 to 120.0 °C
mV Range ±2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV ± 1LSD
mV Relative Offset ±2000.0 mV
EC Resolution 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 μS/cm)
TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt
TDS Accuracy ±1% of reading (±0.01 ppm)
EC/TDS Temperature Compensation disabled, linear and non-linear (natural water)
Temperature Correction Coefficient 0.00 to 10.00 %/°C
Reference Temperature 5.0 to 30.0 °C
Cell Constant 0.0500 to 200.00